[index] [home]

Tweet

Aoyue Int 852 hot air station temperature measurements

Done on 2014-09-04. YMMV w.r.t. absolute temperature; I guess performance can differ between different stations. However, temperature stability regardless of airflow is IMHO ok for this station - I'm quite pleased.

Setup

TC kapton-taped to handpiece; tip of TC approx 2mm in front of, and in the center of 5.5mm inner diameter nozzle. TC + meter have approx 2.5 % max deviation. Measured at approx 21 degC; airco + fan on.

Action

measure temp at various temperatures and airflows. Wait until temperature stable before recording measurement. During operation, temperature goes about 5 degC above and below the recorded value.

note: didn't measure higher temperatures, since they are not considered useful to me

Result (temperatures in deg C)

|             set |
|            temp |                                   
|      air        |                                   
|      speed      | 100 | 125 | 150 | 175 | 200 | 225 | 250 | 275 | 300 |
|      -----------+-----+-----+-----+-----+-----+-----+-----+-----+-----+
|               1 | 130 | 155 | 180 | 205 | 230 | 252 | 275 | 305 | 328 |
|             ----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
|               2 | 145 |  -  | 185 |  -  | 232 |  -  | 276 |  -  | 324 |
|             ----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
|               4 | 142 | 163 | 186 | 206 | 227 | 242 | 270 | 294 | 329 |
|             ----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
|               6 | 141 |  -  | 178 |  -  | 216 |  -  | 262 |  -  | 307 |
|             ----+-----+-----+-----+-----+-----+-----+-----+-----+-----+
|               8 | 135 | 156 | 176 | 195 | 218 | 240 | 260 | 283 | 308 |
|             ----+-----+-----+-----+-----+-----+-----+-----+-----+-----+