Aoyue 868 hot air station temperature measurements

Done on 2014-06-09. YMMV, because I am guessing performance differs quite a lot between different stations.

Setup

TC kapton-taped to handpiece; tip of TC approx 2mm in front of, and in middle of nozzle. TC + meter have approx 2.5 % max deviation. Measured at approx 21 degC; airco + fan on. Used default (middle size) nozzle.

Action

measure temp at each temp-setting (1..8); start at low air velocity, wait until temp stable, measure, then advance air-velocity until drop in temp w.r.t. previous velocity is >= 20 degC

note: didn't measure temp-settings 7 and 8, since they are considered too high

Result

|           temp  |
|                 |                                   
|      air        |                                   
|      speed      |  1  |  2  |  3  |  4  |  5  |  6  |
|      -----------+-----+-----+-----+-----+-----+-----+
|               1 | 193 | 206 | 231 | 281 | 336 | 385 |
|             ----+-----+-----+-----+-----+-----+-----+
|               2 | 184 | 204 | 230 | 270 | 327 | 367 |
|             ----+-----+-----+-----+-----+-----+-----+
|               3 | 180 | 196 | 220 | 264 | 315 | 359 |
|             ----+-----+-----+-----+-----+-----+-----+
|               4 | 165 | 187 | 210 | 240 | 293 | 344 |
|             ----+-----+-----+-----+-----+-----+-----+
|               5 | 144 | 159 | 180 |  -  |  -  | 300 |
|             ----+-----+-----+-----+-----+-----+-----+
|               6 |  -  |  -  |  -  |  -  |  -  |  -  |
|             ----+-----+-----+-----+-----+-----+-----+